北京东方圆通科技发展有限公司
 
Beijing Oriental Technology Development Co.,Ltd

 

 
UNISCAN1000金属及放射性探测门| PM700A高灵敏度步行者γ入口探测器| RTM910车辆出入口放射性物质监测门系统| VM250A车辆入口γ探测器| HDS100GGN型γ谱仪手持式γ中子巡测仪| ABPM203便携式αβ气溶胶监测仪| γ辐射环境连续监测系统(高压电离室辐射监测仪)| SAM940 型手持式同位素识别仪(也称γ能谱分析仪)|


                                                                                     

用途:

       自动扫描监测γ辐射,主要用于监测来自U235或Pu239的γ射线辐射,适用于铀浓缩
工厂,核武器工厂,核武器储存场所,核试验室,核废物处理厂,核废物堆放场及其
他场所, 可测出3g浓缩铀或0.08gPu239(按ASTM Standard C 1169 for Category Ⅲ*测试)

构件:

①立柱2根;
②横柱1根;
③探测器,每根主柱上装有2个有机塑料闪烁体探测器,每个探测器体积为36″(高)
x10″(宽)x1.5″(厚)(90x25x3.8cm3),全系统总探测器体积为2080吋3(约
35.4升), 探测器的5个表面以0.375″厚(约10mm)的铅板屏蔽;
④控制器,一台SC-770的控制器装于主柱上,带256K存储器,可至少存储3个月的
读数,带有一个LCD(液晶显示屏),4行x16字符,带有数字键盘及RS-232通讯
端口;
⑤一台SCA-775单道分析仪,装在副柱上;
⑥远红外位置探测器一个;
⑦提供声音和视觉报警指示;
⑧内置电池,可充电锂电池,可连续供电,供系统连续运行24小时;
外形尺寸:84″(高)x22″(宽)x8″(厚)(214x56x20cm)
重 量:每柱约400磅(182kg)
选 购 件:AM-270报警器,可提供远距(距监测器最大距离300呎(约90米)的声音和视
觉报警。
产 地:美国TSA公司

TSA's PM-700A and PM-700AGN monitors are stand-alone, pedestrian portal monitors with excellent sensitivity and reliability. The PM-700A's large detectors and unique detection algorithm improve its performance to the point that it can achieve ASTM Standard C 1169 Category III* sensitivity for SNM.
All of the essential components are contained in the pillars; radiation detectors, controllers, and occupancy detector. The systems operate from an internal battery. The battery is constantly charged from the site's ac line during normal operation. In the event of a power outage, the battery permits continued operation for at least 24 hours.
Model PM-700AGN adds neutron detection capability to the basic PM-700A. Both models are equipped with RS-232 and Ethernet communications capability.
The PM-700A and PM-700AGN systems utilize TSA's model SC-770 controller in the master pillar, and model SCA-775 single channel analyzer in the slave pillar. TSA's AM-270 provides audible and visual alarm indications.
OPERATION: After the initial site preparation is completed, the systems can be installed and operating in less than an hour. When the system is powered up, it acquires an initial background. The process takes twenty seconds. The background is continually updated until the system is occupied.
When the infra-red detector senses occupancy, the system starts comparing the current count to the most recent background data. Alarm comparisons are made every 200ms. If the count exceeds the alarm level, both audible and visual alarms will be triggered. The system monitors itself and indicates low and high background conditions. A closed circuit tamper output is available for connection to the AM-270 or site security system. System status is continuously updated on the SC-770 display.
 
 
 
These monitors are designed to automatically scan pedestrian traffic without the need for frequent calibration. They are intended for applications where the relatively low energy emissions from 235U and 239Pu are the main concern. They are currently in use at uranium enrichment plants, weapons manufacturing plants, weapons storage sites, nuclear laboratories, nuclear waste disposal, and storage sites where protection of SNM is essential.
Neutron monitoring adds the capability of detecting shielded neutron emitters.
Both models share TSA's unique design features of high sensitivity and reliable operation in variable background environments. These systems cover most pedestrian monitoring applications. TSA's expert engineering staff can adapt them to meet special requirements, if necessary.
 
 
 
Specifications

SENSITIVITY:
PM-700A:
Will detect 3g HEU or 0.08g 239Pu when tested in accordance with ASTM Standard C 1169 for Category III* monitors
PM-700AGN:
Will detect 10g HEU or 1g 239Pu when tested in aaccordance with ASTM Standard C 1169 for Catagory II* monitors; will detect 120g of 99% shielded 239Pu based solely on neutron detection
DETECTORS:
PM-700A:
Two, 36"h x 10"w x 1.5"d (90 x 25 x 3.8cm) organic plastic scintillator detectors per pillar; provides approximately 2,080 in3 (35.4 liters) of detector volume per system
The detectors are shielded on five sides with 0.375" (10mm) of lead
PM-700AGN:
Two, 30"h x 6"w x 1.5"d (75 x 15 x 3.8cm) organic plastic scintillator detectors and two 2" diameter x 36" (5 x 91cm) 3He neutron detectors per pillar
The detectors are shielded on five sides with 0.375" (10mm) of lead
ALARM LEVEL:
SPRT for neutron, N*sigma for gamma, entered from the numeric keypad
FALSE ALARM RATES:
Typically less than 1 in 1,000 passages, as tested in accordance with ASTM Standard C 1169*
ALARM INDICATION:
Gamma alarms are indicated by a red strobe light mounted on the master pillar. High and low faults along with other fault conditions are indicated by an amber light. Neutron alarm is indicated by a blue strobe light.
DISPLAY:
Alphanumeric LCD, 4 lines x 16 characters
COMMUNICATIONS:
Both models are equipped with RS-232 and Ethernet communications capability
DATA STORAGE:
256k bytes of flash memory is used to store average hourly background data and alarm data. Under normal conditions the memory should be adequate to store data for at least 3 months of operation.
POWER REQUIREMENTS:
90 - 250 Vac, 47 - 63 Hz, less than 100 VA
BATTERY LIFE:
Greater than 24 hours normal operation
DIMENSIONS:
PM-700A:
84"h x 22"w x 8"d (214 x 56 x 20cm)
PM-700AGN:
84"h x 26"w x 8"d (214 x 66 x 20cm)
WEIGHT:
PM-700A:
~400 lb (182kg) per pillar
PM-700AGN:
~600 lb (273kg) per pillar
ENVIRONMENTAL:
-30 to 122°F (-34 to 50°C); designed for use in a sheltered area
OPTIONAL COMPONENTS:
Heaters, AM-270



北京东方圆通科技发展有限公司 版权所有 @2008
公司地址: 北京市昌平区西环路24号楼
京ICP备06015360号
电话: 010-51288063, 13301057943 电子邮件: dongfangyt2@tom.com